Steel Fire Door With Fire-Resistant Glass Vision Panel

Send Inquiry
Steel Fire Door With Fire-Resistant Glass Vision Panel
Details
Mandatory Technical Parameters of Main Frame 1. Door frame & leaf steel: Frame ≥1.2mm cold-rolled galvanized steel, leaf skin ≥0.8mm, integrally bent & welded with full well-shaped reinforcing keels. Interior filled with compacted dust-free non-combustible perlite fire core boards,...
Category
Fire Door
Share to
Description

Hebei Hong'an Fire Door Co., Ltd. is one of the most reliable manufacturers and suppliers of steel fire door with fire-resistant glass vision panel in China. If you're going to buy durable steel fire door with fire-resistant glass vision panel made in China, welcome to get free sample from our factory. All customized products are with high quality and low price.

 

 

Mandatory Technical Parameters of Main Frame

1.Door frame & leaf steel: Frame ≥1.2mm cold-rolled galvanized steel, leaf skin ≥0.8mm, integrally bent & welded with full well-shaped reinforcing keels. Interior filled with compacted dust-free non-combustible perlite fire core boards, no collapse or delamination in fire. Hot-dip galvanizing + fluorocarbon coating optional for coastal salt spray corrosion resistance.

2.Smoke sealing system: Full-length intumescent strips (expansion ratio ≥5x). Smoke leakage: ≤20m³/h (single leaf), ≤30m³/h (double leaf) under 25Pa differential pressure. Door gap ≤2mm, inspected by 0.1mm feeler gauge. Double doors with middle joint strips and liftable bottom airtight seals.

d5e5a7e24db6429b0ec5d303629812ca

Core Fire-resistant Glass Selection & Classification

Only certified fire-resistant glass with official identification is permitted. Ordinary tempered or insulating glass is not allowed.

Class A Insulated Composite Fire Glass

Grout-filled composite glass with thickness ≥35mm, providing both fire integrity and thermal insulation. Rated A0.50 / A1.00 / A1.50 (0.5h/1.0h/1.5h). Suitable for high-risk areas such as electrical rooms, fire wall openings and stairwells, preventing back-face ignition during fire.

Class C Non-insulated Cesium-Potassium Fire Glass

Only guarantees fire integrity with fire resistance rating ranging from 0.5h to 3.0h. Mostly used for corridor passages and office partitions. It merely blocks flame penetration without mandatory thermal insulation requirement.

Installation Requirements

Glass edges are sealed with fireproof elastic strips and sealant with reserved expansion gaps to prevent thermal cracking and falling off. The vision window size must strictly conform to type test report specifications; oversized dimensions are non-compliant.

 

 

 

Hot Tags: steel fire door with fire-resistant glass vision panel, China steel fire door with fire-resistant glass vision panel manufacturers, suppliers, factory

Send Inquiry